
Pharmaceutical
From small manual batches to 150,000 capsules per hour on automatic lines, for powders, granules and pellets.
Get in touch! +91-7435031331
Compare manual, semi automatic and automatic capsule fillers for development work and production batches. Choose by capsule size, formulation, target output and operator involvement, with automatic models reaching 150,000 capsules per hour on the LCF-150.
Lodha International LLP is a capsule filling machine manufacturer established in 1995. The range covers manual bench-top fillers, semi automatic equipment, fully automatic production machines and a compact automatic lab model. Selecting a filler means matching the capsule shell, fill material and batch requirement to the dosing method and operator workload. This guide helps you shortlist the right machine; each model page carries the full technical specification. The broader capsule machines category also includes equipment for polishing, printing and counting; this page focuses on the filling stage.
Our seven capsule fillers fall into four groups. Start with how much hands-on work suits your process, then compare output, capsule sizes and fill materials.
A manual capsule filling machine gives the operator direct control of loading, separation, powder spreading, tamping and closing. The 100-hole filler includes an orienter, while CFM 300 fills 300 capsules at a time. The standard manual filler reaches 7,500 to 8,000 capsules per hour. Manual operation suits small batches, R&D work and growing herbal or nutraceutical units.
The semi automatic capsule filling machine combines automatic loading and dosing with operator handling of the loading rings. LSCF-35 uses a single ring and LSCF-45 a double ring. A four-speed auger and variable filling-table speed suit different powders and pellets. The operator moves the rings between the separation, filling and closing stages, so output depends on capsule size and operator skill.
The automatic LCF range carries capsules through rectification, separation, dosing and joining on a turntable. Models run from LCF-25 to LCF-90. For higher volumes, the LCF-150 high speed model adds tamping-pin powder dosing, vacuum separation and automatic rejection of non-separated or badly closed capsules.
LI-LCF LAB is designed for small laboratory and R&D operations. It combines feeding, separation, dosing, joining and ejection in a compact automatic machine with PLC and touch-screen control. It fills up to 3,000 capsules per hour with powder or 2,000 with pellets, with format parts for sizes 00 to 4, giving development teams automatic filling without a full production machine.
Shortlist a model by output, capsule sizes and fill material. Actual output depends on capsule size, formulation, capsule quality and operator skill.
| Model / product | Type | Output / hour | Capsule sizes | Fill material | Operation |
|---|---|---|---|---|---|
| Manual Capsule Filling Machine | Manual | 7,500-8,000 | 000 to 5 | Powder | Manual trays, tamping and closing |
| LI-CFM 100 + LI-MCL 100 | Manual with orienter | Up to 4,000 | 00 to 5 (by model) | Powder | 100 holes; manual orienting and filling |
| CFM 300 | Manual | Up to 6,000 | 00, 0, 1, 2, 3, 4, 5 | Powders, granules, pellets | 300 holes; manual filling |
| LSCF-35 / LSCF-45 | Semi automatic | Up to 35,000 / 45,000 | 00, 0, 1, 2, 3, 4, 5 | Powders, granules, pellets | Single / double ring; operator transfers |
| LCF-25 / 40 / 70 / 90 | Automatic | 25,000 / 40,000 / 70,000 / 90,000 | 00, 0, 1, 2, 3, 4 | Powder, granules, pellets and combinations | Turntable; vacuum separation; tamping pins |
| LCF-150 | High speed automatic | 150,000 | 00, 0, 1, 2, 3, 4, 5 | Powders, pellets, tablets, micro-tablets | PLC / HMI; tamping-pin powder dosing |
| LI-LCF LAB | Lab automatic | Up to 3,000 powder / 2,000 pellets | 00, 0, 1, 2, 3, 4 | Powder, pellets; optional dosing stations | PLC / HMI; variable speed |
Output is per hour and varies with capsule size and formulation. Full specifications are on each model page.
An automatic capsule filling machine moves each capsule through a series of stations, removing the tray and ring handling of manual and semi automatic machines. The LCF range rectifies, separates, doses, joins and rejects automatically, and its enclosed dosing system with dust suction keeps powder contained around the filling area.
Choose the LCF-25 to LCF-90 for 25,000 to 90,000 capsules per hour, or the LCF-150 for up to 150,000. Share your capsule size and formulation, and our engineers will match the dosing system and confirm fill-weight performance for your product.
Every capsule filler follows the same five steps. What changes from manual to automatic is how much of each step the machine does for the operator.
Each capsule size needs its own format parts, and each fill material needs a matching dosing system. HPMC and vegetarian shells are supported on the CFM 300 and the LI-LCF LAB.
| Product / range | Capsule sizes | Shells and fill materials |
|---|---|---|
| 100-hole filler | 00 to 5 (by model) | Powder; one machine variant per size group |
| CFM 300 | 00-5 | Hard gelatin, HPMC and vegetarian shells; powders, granules and pellets |
| Semi automatic LSCF | 00 to 5 | Powders, granules or pellets |
| Automatic LCF | 00 to 4 | Hard gelatin shells; powders, granules, pellets and combinations |
| High speed LCF-150 | 00-5 | Hard gelatin shells; powders, pellets, tablets and micro-tablets |
| LI-LCF LAB | 00-4 | HPMC and vegetarian shells; powder and pellets; optional dosing stations |
The LI-LCF LAB can also be configured with micro-dosing, tablet, liquid and combination filling stations. Tell us which stations you need when you ask for a quotation.
List the number of capsules required per batch and the available filling time. Use that requirement to compare manual, semi automatic and automatic capacities.
List every capsule size and shell type you use. Each size needs format parts, and the 100-hole filler uses a separate variant per size group.
State whether the formulation is powder, granules, pellets or a combination. Include the target fill weight and any material-handling concerns.
Consider tray handling, tamping and ring transfers alongside machine speed. Decide which tasks your team can perform consistently over the planned batch.
Plan for how often you clean and change size. Tell us every formulation you will run so changeover can be planned with the machine.
Automatic LCF machines use SS 316 for contact parts and SS 304 elsewhere. The manual filler uses SS 304 contact parts.
IQ, OQ and DQ documents and test certificates are available on request for the LI-LCF LAB. List the documents your auditors need.
Send shell sizes, formulation and planned output for a model recommendation.
Ask an engineerOur capsule fillers serve pharmaceutical, nutraceutical, Ayurvedic and research users. The dosing system is matched to each formulation, from fine powders to pellets.

From small manual batches to 150,000 capsules per hour on automatic lines, for powders, granules and pellets.

Supplement powder blends in hard gelatin, HPMC and vegetarian capsules, with the CFM 300 suited to small batches.

Herbal and Ayurvedic powder blends, with the CFM 300 suited to small herbal batches.

The 100-hole filler suits R&D and small clinical trials, and the LI-LCF LAB brings automatic filling to development labs.
Lodha International LLP has manufactured pharmaceutical machinery since 1995 and supplies equipment for filling and related processing operations.
The range includes bench-top manual fillers, semi automatic ring machines, automatic production models and a compact automatic laboratory option.
Change parts are made for the capsule sizes you run, so one machine can handle several formats.
Automatic machines use SS 316 for every product-contact part and SS 304 for the frame and covers.
IQ, OQ and DQ documents and test certificates are available on request for regulated labs.
Lodha exports pharmaceutical machinery to more than 50 countries. Tell us your destination country and required configuration, and we will quote accordingly.
Lodha exports pharmaceutical machinery to more than 50 countries. Use the country links below to explore existing local supplier pages, and include your destination in a capsule filling enquiry. Agree the selected model, format parts, utilities and documentation requirements as part of the quotation.
Linked countries open our local supplier page.
Tell us your formulation, capsule sizes, shell type and target output. Include your country and any dosing or documentation requirements.